INFO & QUOTE REQUESTS: info@saphonyx.be

Henkel Adhesive Technologies

The Henkel laboratory in Chalon-sur-Saône

Testing, process sequence development, analysis and training in surface treatment

In 2011, Henkel opened a laboratory dedicated to surface treatment in Chalon-sur-Saône (Saône-et-Loire), on the former premises of the Kodak research centre. The 250 m² laboratory houses pilot lines for semi-industrial trials, analytical and measuring instruments, and paint application facilities.

The laboratory works with technical products and on actual production lines, carrying out trials, process approvals and process validation. Saphonyx customers can use the laboratory for their trials.

Aerial view of the Henkel laboratory site in Chalon-sur-Saône

The laboratory site in Chalon-sur-Saône.

What the laboratory does

  • Product formulation;
  • Defining treatment sequences, that is, the order of the baths, and conducting validation trials;
  • Analysis of customers’ baths;
  • Training for users, in the laboratory or on site.

The Chalon laboratory is part of Henkel’s global network of surface treatment laboratories in Europe (including Düsseldorf), North America and Asia.

Henkel’s surface treatment laboratory in Chalon-sur-Saône

Laboratory benches and measuring instruments.

Facilities and equipment

Equipment Use
Stock of several hundred raw materials and finished products Formulating products and preparing test baths
Mixers for powders and liquids Preparing formulations in the laboratory
Carbon analysis furnace and goniometer Measuring the effectiveness of degreasers
Portable X-ray fluorescence analysers (Niton) Measuring conversion coating weight: zirconium, titanium, chromium levels…
Automatic titration equipment, spectrophotometers and ion meters Monitoring test baths
Goniometer

Goniometer: measuring degreaser effectiveness.

X-ray fluorescence measurement

Coating weight measurement by X-ray fluorescence.

Automatic titration

Bath monitoring by automatic titration.

Raw material stock

Raw materials and finished products.

Simulating your production line

Facility Laboratory equipment
Surface treatment Dip and spray pilot lines
Paint application Curing oven, powder coating booth, liquid paint booth
Degreasing trials Ultrasonics, electrolytic degreasing, foam gun, controlled agitation
Paint adhesion Mandrel bend, cross-cut, impact and Erichsen cupping tests

The laboratory reproduces your production conditions to define and validate a treatment sequence before you implement it on your line.

Phosphating process diagram: degreasing, rinse, surface conditioning, phosphating, rinse, passivation

Example of a simulated treatment sequence: degreasing (by spraying and dipping), rinse, grain refinement, phosphating, rinse, passivation.

Pilot dipping line

Dip pilot line.

Pilot spray line

Spray pilot line.

Paint application in a paint booth

Paint application in a booth.

Ultrasonic degreasing tank

Ultrasonic degreasing.

Application with a foam gun

Degreasing with a foam gun.

Cross-cut adhesion test

Cross-cut adhesion test.

Checks and analyses

Area Analyses
Monitoring customers’ process baths Concentrations, contaminants, metals…
Corrosion resistance Neutral salt spray, acetic acid salt spray, poultice test, QCT (condensation), Ford bath test…
Conversion coatings Coating weight and crystallography
Bath hygiene Bacteriological tests
Identifying the causes of defects EDX and ESCA surface analyses
Specialist analyses ICP, gas chromatography (GC) and HPLC, COD, flash point

Some of these analyses are carried out in partnership with the Intertek laboratory.

Salt spray chambers

Salt spray chambers.

Test specimens after corrosion testing

Test specimens after corrosion testing.

Phosphate crystals viewed under an electron microscope

Crystallography of a phosphate coating.

Composition profile of a zinc-magnesium-aluminium coating

Composition profile of a Zn-Mg-Al coating.

A training centre

The laboratory is also a training centre. The programmes cover the full range of products and technologies: they enable your teams to master the products and processes, as well as the health and safety rules (CLP, REACH).

  • Theoretical training at the Chalon laboratory;
  • Practical training at your site, tailored to your installation.

Example of course content: the phosphating reaction, 2 Zn²⁺ + Me²⁺ + 2 H₂PO₄⁻ + n H₂O → Zn₂Me(PO₄)₂·nH₂O + 4 H⁺ (Me = Zn, Fe, Mn or Ni), and titration of a bath to monitor its concentration.

Diagram of bath titration with 0.1 N hydrochloric acid

Titration of the free alkalinity of a bath: a 10 mL bath sample with phenolphthalein is titrated with 0.1 N hydrochloric acid.

Laboratory successes

BONDERITE C-IC 212

Acid degreaser and deoxidizer for use before conversion coating: removes oxides and scale, particularly those formed during laser cutting.

For immersion or spray application. Its mild action prevents over-pickling. Also suitable before electroless plating, electroplating or adhesive bonding.

Technical data sheet (PDF) →

BONDERITE M-NT 40043

Combined degreaser and conversion coating for treatment tunnels with two or more stages. Replaces amorphous (iron) phosphating.

Promotes paint adhesion and provides corrosion protection, using only 1/20 to 1/100 as much phosphate as iron phosphating.

Technical data sheet (PDF) →

BONDERITE M-NT 65000 AERO

Conversion coating for aluminium and its alloys, free of hexavalent chromium: replaces the ALODINE 1200 chromate process (now BONDERITE M-CR 1200).

Promotes paint adhesion, protects unpainted parts and provides low electrical contact resistance. For applications subject to the MIL-C-5541 standard.

Request the technical data sheet →

BONDERITE C-MC 21130

Cleaner for removing solvent-based and water-thinnable paints, uncured cathodic electrocoatings and adhesives from application equipment and booth walls and floors.

Free of chlorinated, petroleum-based and oxygenated solvents; non-flammable. Use neat or diluted to 20% at room temperature; remove with a water rinse.

Technical data sheet (PDF) →

Request a laboratory test

Each test requires a laboratory work request (DTL). We prepare it with you and explain how to send us your parts. To prepare the request, we need the following:

  • details of your site, your line and the product currently in use;
  • the metal to be treated and the coating applied afterwards;
  • your current treatment sequence: for each stage, the product, concentration, temperature, spray pressure and treatment time;
  • the products to be tested and the tests you require, either on your parts or on laboratory test specimens;
  • whether you need the parts returned and the date by which you would like a response.

You are welcome at the laboratory

You can visit the laboratory to:

  • observe your tests;
  • validate the proposed solutions;
  • draw up action plans and study programmes;
  • learn how to use our products.

The aim: to work together to keep your production running over the long term.

See also:
Henkel Adhesive Technologies →
Henkel worldwide →
Our surface treatment products →

Need advice?

Would you like to have your parts tested or validate a treatment sequence? Tell us about your metal, your line and your requirements: we will prepare the work request with you and send you the results.