Process line cleaning
Scale, phosphate deposits and sludge foul the tanks, tunnels, pipework and nozzles of surface treatment lines: thermal efficiency drops, pumps and nozzles clog, and treatment becomes uneven.
Periodic descaling, followed by neutralisation and rinsing, restores the line to working order.
- Drain the baths and rinse the tanks and tunnel walls with pressurised water to flush out the sludge.
- Inspect each stage to determine the descaler concentration and contact time.
- If grease is present (in the degreasing stages), carry out alkaline cleaning first.
- Circulate the descaling solution using the line pumps; descale heavily clogged nozzles separately in a small tank.
- Neutralise the spent solution before discharge, rinse until the pH is between 6 and 8, then make up fresh baths.
Recommended products
BONDERITE C-IC SL
Liquid acid descaler for surface treatment installations (formerly NOVOX SL); contains a corrosion inhibitor for ferrous metals and is free from phosphoric acid
Washing and phosphating tanks and tunnels, heat exchangers; for circulation: 100 to 300 g/l, 30 to 70 °C, 1 to 8 h, 1 to 2 bar
BONDERITE C-IC DT
Phosphoric acid-based liquid descaler with a corrosion inhibitor (formerly NOVOX DT)
Saphonyx procedure: 15% by volume, 40 to 50 °C, spray for 8 to 12 h, then neutralise
BONDERITE C-MC DSR-16
Sulfamic acid-based powder descaler with inhibitors (formerly MAGNUS DSR 16): eliminates the need to handle concentrated liquid acids
5 to 10%, from room temperature to 60 °C; non-foaming
BONDERITE C-IC 4368
Inhibited acid descaler, free from sulphuric, hydrochloric and nitric acids (formerly TURCO 4368): for surface treatment equipment and boiler circuits
Immersion or circulation; 12 to 20% by volume, 20 to 80 °C
BONDERITE C-AK STL
Strong alkali (formerly NOVACLEAN STL): for neutralising the descaling solution at the end of the operation or for light cleaning of the line
Neutralisation: add in small increments (exothermic reaction) until the pH is between 5 and 8; light cleaning: spray at 15% by volume and 40 to 50 °C
BONDERITE C-NE N
Neutral deoxidizer, also used as a sequestering additive for degreasing-phosphating baths
0.5 to 2% in the bath to facilitate descaling
See also:
M.R.O. page, “Machine cleaning” →
Surface treatment page →
Need advice?
Tell us what you need to treat, on which substrate and with what equipment: we will recommend a product and method and send you the technical data sheets and safety data sheets or a quotation.