INFO & QUOTE REQUESTS: info@saphonyx.be

W.T. range

Descaling

Limescale reduces the thermal efficiency of equipment, increases energy consumption and can block pumps and spray circuits.

For the chemical descaling of heat exchangers, cooling circuits, boilers and surface treatment tanks, Saphonyx offers BONDERITE inhibited acid descalers. Water conditioning (inhibitors, biocides) is handled by a specialist partner.

  • Circulate the descaler through the system or immerse removable equipment.
  • Degreasing-phosphating baths: adding the C-NE N additive before the acid descaler avoids the need to drain the bath.
  • Before discharge, check that the effluent complies with current legislation.

Recommended products

BONDERITE C-IC SL

Liquid acid descaler (formerly Novox SL), inhibited for ferrous metals and free of phosphoric acid: for washing or phosphating tanks and tunnels, heat exchangers and cooling circuits.

Apply by circulation or immersion; for spray application, use 100 to 300 g/L at 30 to 70 °C for 1 to 8 h depending on the degree of scaling, at 1 to 2 bar.

Technical data sheet (PDF) →

BONDERITE C-IC 4368

Inhibited acid pickling agent and descaler (formerly TURCO 4368), free of sulphuric, hydrochloric and nitric acids; does not attack the base metal and requires no neutralisation.

For descaling boiler and heater circuits, even while still warm, by immersion or circulation; use at 12 to 20% by volume at 20 to 80 °C.

Technical data sheet (PDF) →

BONDERITE C-NE N

Near-neutral sequestering additive (formerly NOVACLEAN N) that facilitates descaling of degreasing and degreasing-phosphating baths.

Add 0.5 to 2% to the bath, agitate for 15 min, then add the acid descaler (approximately 8 to 10%).

Technical data sheet (PDF) →

BONDERITE C-IC R

Acid detergent (formerly NOVOX R) for removing scale and mineral deposits.

For water circuits, use at 10 to 20%; for immersion, use at concentrations ranging from 50% to undiluted.

Technical data sheet (PDF) →

See also:
Cleaning Machines page, “Ultrasonic cleaning”: “Descaling” tab →
Water Treatment page →

Need advice?