Corrosion protection
Protect parts between operations and during storage, and limit attack by acid baths
The metalworking industry requires active corrosion protection for parts. Intermediate storage has become more frequent, and parts pass through a wider range of environments, some of them harsh. Oxidation of bare parts is mainly due to contact with oxygen in the air and fluctuations in humidity and temperature.
Henkel products cover the various types of protection needed between operations and for short- or long-term storage.
Protection methods
Corrosion protection creates a barrier against external attack using various methods:
- wrapping in Zerust® Excor® corrosion-inhibiting film from Acobal;
- painting;
- protective oils and dewatering fluids (water-displacing fluids);
- film-forming amine;
- phosphating;
- conversion coating;
- electroplated coatings (zinc plating, electrogalvanizing) or hot-dip galvanizing;
- zinc thermal spraying.
Testing corrosion protection
Standardised corrosion tests assess the performance of each method:
| Test | Standard |
|---|---|
| Neutral salt spray (NSS), acetic acid salt spray (AASS) or copper-accelerated acetic acid salt spray (CASS) | ISO 9227 |
| Kesternich (sulphur dioxide atmosphere) | DIN 50018 / ISO 6988 |
| Cast iron chip corrosion test | DIN 51360 |
| Resistance to liquids by immersion | ISO 2812 |
Film-forming protection
BONDERITE S-PR 3
Oil for temporary corrosion protection (formerly P3-GEROCOR 3). Leaves an oil film of approximately 1.5 g/m². Provides 3 to 6 months of protection in covered storage
Substrates and methods: Steel, cast iron; immersion – spray gun; use neat at room temperature (15 to 30 °C) for 0.5 to 3 min; applications: protection of parts during storage and shipping
BONDERITE S-FN 6764
Emulsion for medium-term corrosion protection (formerly P3-PREVOX 6764). Neat oil with added corrosion inhibitors; dry or oily appearance depending on concentration
Substrates and methods: Clean steel and cast iron parts; immersion – fine spray – spray; dry appearance at 2 to 5%, oily appearance at 5 to 20%; room temperature; drying recommended; applications: temporary protection of parts for storage in an enclosed warehouse; remove with a hot solution of BONDERITE C-NE 175
BONDERITE S-PR 97-10
Water-emulsifiable product for temporary corrosion protection (formerly EMULPON 97-10). Designed for very soft water (as low as 1 °dH); not recommended above 20 °dH
Substrates and methods: Steel, cast iron; immersion – spray, particularly in the final stage of multistage systems; immersion: 10 to 40 g/l, spray: 10 to 30 g/l; 10 to 80 °C; 0.5 to 3 min; applications: protection of steel and cast iron for subsequent storage in an enclosed, heated warehouse
BONDERITE S-FN AQUASTOP
Water-repellent fluid with corrosion-inhibiting properties (formerly TURCO AQUASTOP). Displaces water from parts: no drying step is needed. The residual film provides temporary protection during indoor storage
Substrates and methods: Metal parts; does not attack metals; protects ferrous metals from oxidation; immersion (usual method) – fine spray – brush; ready to use neat; can be diluted with white spirit for a thinner film; applications: drying and protection of parts between machining operations, after alkaline degreasing, electrolytic treatment, blackening or paint stripping
Passivation
BONDERITE S-FN 7400
Aqueous corrosion protection product (formerly P3-PREVOX 7400). Organic corrosion inhibitors, free from mineral oil; non-foaming
Substrates and methods: Steel, cast iron (does not inhibit corrosion on light metals or other non-ferrous metals); dipping – spray – fine spray, particularly in the final zone of a tunnel; steel: 5 to 20 g/l, cast iron: 15 to 30 g/l; 15 to 80 °C; more than 30 s; applications: passivation of steel and cast iron in leak-test tanks for hollow components, cooling circuits and degreasing baths before painting
BONDERITE S-FN 6304
Mildly alkaline temporary protection, free from oil and amines (formerly P3-PREVOX 6304). Provides sufficient protection for storage between operations and for hydraulic testing
Substrates and methods: Metal parts; on non-ferrous metals, do not exceed the specified parameters (risk of discolouration); spray – immersion; spray: 1 to 5 g/l, immersion: 3 to 10 g/l; 20 to 60 °C; 20 to 60 s; applications: temporary protection of parts stored between operations and during hydraulic testing
BONDERITE S-FN 5081
Aqueous temporary corrosion protection, free from mineral oil (formerly P3-PREVOX 5081, previously S-PR 5081). Organic corrosion-inhibiting components; no troublesome foaming between 20 and 80 °C
Substrates and methods: Steel, cast iron (long contact times may discolour non-ferrous metals); immersion – spray, particularly in the final zone of a multi-zone degreasing system; 10 to 30 g/l; 20 to 80 °C; 0.5 to 3 min; applications: passivation before intermediate storage in enclosed premises; additive for leak-test water and cooling water
BONDERITE S-FN T320
Oil-free alkaline passivation agent (formerly P3-T 320). Converts iron salts remaining after pickling into complex salts that can be removed, leaving a uniform, bright surface.
Substrates and methods: Pickled steel, degreased and pickled sheet metal; cast iron; immersion – spray; iron salt removal: 20 to 40 g/L, 20 to 60 °C, 1 to 5 min; passivation: 2 to 5 g/L at 65 °C; Applications: Post-treatment of steel pickled in hydrochloric or sulphuric acid and final passivation before storage
VCI protection (volatile corrosion inhibitors)
ZERUST® / EXCOR® (Acobal)
Packaging with volatile corrosion inhibitors (VCI). Films, covers and bags, papers, foams, emitter capsules
Substrates and methods: Metal parts and subassemblies; packaging for storage and transport; Applications: Corrosion protection without oil or grease – see the Zerust Excor range
Full range: Zerust® Excor®: anti-corrosion packaging.
Inhibitors for acid pickling baths
Strong acids remove oxide and mill scale before subsequent stages of a production line, or are used, for example, to clean pipework during maintenance. They also attack the base metal and cause substantial metal loss; hydrogen entering the metal makes it brittle. Inhibitors reduce acid attack on the metal and prevent hydrogen embrittlement without interfering with the removal of oxide or limescale.
Saphonyx offers a range of inhibitors and additives that limit acid attack in hydrochloric, sulphuric, hydrofluoric, phosphoric, acetic, sulphamic, citric and oxalic acid pickling baths, particularly for:
- hot-dip galvanizing;
- electroplating;
- deoxidation;
- descaling with hydrochloric acid;
- pickling steel, cast iron and galvanized steel.
Hot-dip galvanizing
Electrolytic zinc plating and phosphating
The inhibitors
BONDERITE S-AD 31A
Liquid, chloride-free pickling inhibitor (limits acid attack). For phosphoric, sulphuric, amidosulphonic, acetic, citric and formic acids. Former name: Rodine 31 A (BONDERITE S-AD 31A)
Substrates and methods: Steel, cast iron, hot-dip galvanized steel; not for use on electrogalvanized steel; 1 to 5 L per 1,000 L of bath, depending on temperature; Applications: Compatible with phosphoric, sulphuric, sulphamic, acetic, oxalic, formic and citric acids
BONDERITE S-AD 60 /S-AD 1600 IT
Inhibitors that limit acid attack in hydrochloric acid pickling baths. S-AD 60: low-temperature pickling (former name: Rodine 60). S-AD 1600 IT: non-foaming, for static or continuous pickling (former name: Rodine 1600 IT)
Substrates and methods: Steel, cast iron, hot-dip galvanized steel (not for use on electrogalvanized steel); S-AD 60: 0.5 to 5 kg per 1,000 L, 20 to 40 °C; S-AD 1600 IT: 0.8 to 3 kg per 1,000 L of acid, up to 100 °C; Applications: Compatible with hydrochloric acid
BONDERITE S-AD 145L
Inhibitor additive for acid baths (formerly RODINE 145 L).
Intended use: corrosion inhibitor (Henkel safety data sheet 225416); contact us for compatible acids and dosage.
See also:
Deoxidation, rust removal and descaling →
Phosphating →
Conversion coating: multimetal and aluminium →
Zerust® Excor®: anti-corrosion packaging →
Surface treatment: all ranges →
Need advice?
Tell us about your parts, substrates, soils and equipment: we will recommend a product and method and send you the technical data sheets and safety data sheets or a quotation.